Instrument Transformers
Call Now8047825271,4070WhatsApp
Isolation Transformer 3000VA
₹ 14,168Power Rating: 3000 VA
Output Voltage: 240 V
Phase: Single Phase
Cooling Type: Dry type/Air cooled
Yashika Industries
Deals in Alwar Call Now8047630760WhatsApp
0.2 kVA Roboart Isolation Transformer
₹ 4,500Body Material: Mild Steel
Phase: Single Phase
Brand: Roboart
Size: 10 x 5 x 9 Inch (L x W x H)
Roboart
Deals in Alwar Call Now7942867622WhatsApp
30 kVA Isolaition Transformer
₹ 1,85,000Voltage Factor: 1.2
Power Rating: 30kVA
Input Voltage: 440 V
Output Voltage: 400 V
V-Tech Enterprises
Deals in Alwar Call Now8043858853WhatsApp
1.5Kva Control Transformer, Winding Material: Copper
₹ 6,000Output Voltage: 220V
Power: 1.5KVA
Phase: Single Phase
Insulation: F Class
Power Transelectro
Deals in Alwar Call Now7949326296WhatsApp
Air Cooled Isolation Transformers
Call Now7942835213WhatsApp
DRISE Power 200 kva To 500 kva Isolation Transformer, For Industrial, 3
Call Now7942548461WhatsApp
Murrelektronik 86151 MST Single Phase Control Isolation Transformer
Call Now7949091705WhatsApp
Instrument Transformers

Price On RequestSkipper has pioneered the design and manufacture of Instrument Transformers over the past three decades. Skipper Instrument Transformers are globally known for consistent accuracy, reliability and maintenance-free operation over life time. Skipper manufactures the entire range of Instrument Transformers viz. : Oil Filled, Outdoor Resin Cast, Indoor/Outdoor Metering Units, Indoor/Outdoord
Oil Filled Current Transformers
Skipper manufactures Oil Filled Current Transformers upto 220 kV class. Skipper make transformers are currently in operation
in challenging locations and have been delivering outstanding performance consistently for over 25 years. These
transformers comply with international quality, safety and environment specifications standards.
Outdoor Potential Transformers
Skipper complements its range of Current Transformers with Potential Transformers. The PTs are usually built up of multi cores designed for Metering and Protection in dead tank construction.
The PTs built in stacked core construction employ high permeability cold rolled grain oriented magnetic steel. The PTs are designed and manufactured in accordance with specific user s specification and are suitable for Indoor / Outdoor application.
Skipper is equipped to Design and Manufacture PTs upto 220 kV Class system voltage, with in-house Testing facilities for conducting all routine Tests. However, Skipper also conducts Type and Special Tests to validate the design at outside NABL accredited Test Laboratories like CPRI and ERDA.
Design
Oil filled current transformers use current transformation principle to convert highline current (in HV system) to a low current reduced by a fixed ratio. The current transformers are designed generally in live tank construction for optimum performance.
The primary winding is manufactured from copper conductor and is placed in the top housing.
The windings are rigid, concentric with uniformly distributed secondary winding to deliver high mechanical strength against short circuit forces.
The secondary windings and the cores are contained in closely fitting rigid shell. The shell is fully insulated from the top housing. The secondary leads are taken to the base passing through a hollow insulator.
Insulation is provided by electrical grade high grade Kraft paper. The fully assembled CTs are dried and oil filled under vacuum in evacuated heating chambers. Optimum insulation and long life is achieved by drying the paper insulation by heat in vacuum. Oil, impregnated under vacuum, complements the insulation.
Construction
Skipper uses brown glazed porcelain insulator with shed profile as per IEC 60815 for the CTs. Optionally grey shade porcelain and other profiles can be offered as per specific requirements. The porcelain insulator is cemented to flanges on both ends for maximum mechanical strength. The top housing contains core coil assembly and is made of corrosion resistant aluminum alloy.
The top of the tank has an oil filling plug. The CT is protected from the vagaries of weather and can withstand extreme temperature variations. Core of wound ring type are manufactured from high quality silicon steel. However, Mu-metal cores are used for select applications. Design, material and process selection ensure that all requirements relating to metering and
protection are met. The secondary winding is uniformly distributed over the circumference of the core to minimize the reactance of the winding. This also ensures accurate transformation ratio. The CT base chamber is fabricated from structural steel. This chamber is provided with secondary terminal box, oil sampling valve and earthling pads.
Skipperseil Limited
Deals in Alwar Call Now8047646232,6004WhatsApp
Oil Cooled Instrument Transformers
Call Now8047697123,5233WhatsApp
Hammond Power Solutions Control Transformers
Call Now8048214079,7977WhatsApp
Single Phase Control Transformer 200 VA (415 VAC to 110 VAC)
₹ 1,800Power Rating: 200 va
Phase: Single Phase
Primary Voltage: 415 VAC
Secondary Voltage: 110 VAC
Shivay Sales Corporation
Deals in Alwar Call Now8047819986,1242WhatsApp
Control Power Transformer
Call Now8048208828,3235WhatsApp
86153 Mst 1-phase Control And Isolation Transformer, Output Voltage: 2x 115 V Ac
Price On RequestStandards: EN 61558-1, EN 61558-2-4, EN 62041 category 0
Test isolation voltage: 4 kV (prim./sec.)
Mounting method: Key-hole mounting
Dimensions HxWxD: 185x192x185 mm
Sonaksh Automation Solutions
Deals in Alwar Call Now8043888961,7596WhatsApp
Oil Cooled Instrument Transformer
Call Now8047697745,5860WhatsApp
Completely Self Protected Distribution Transformers

Price On RequestApplicable Standards : IEC / ANSI /BS / IS / EN /GOST Wide range of CSP transformers in accordance to above standards with different combinations can be manufactured. The CSP transformers are generally designed and manufactured to comply with the IEC publications 60076. CSP feature can be provided in the following range of transformers. Single Phase: 5kVA-167 kVA, Three Phase: 10 kVA-400 kVA, Insulation level 12 KV 24 KV 36 KV Indoor / Outdoor installation Conductor : Copper or Aluminum as per customer requirement CRGO / Amorphous as per customer requirement Hermetically sealed type (with gas cushion / fully filled) / Conventional type (with Conservator) Color : as per customer requirement Cooling arrangement : Corrugation or Pressed steel Radiators Maximum ambient temperature : as per customer specification Top oil Temperature rise : as per customer specification Average winding temperature rise : as per customer specification Concept of CSP transformers CSP technology is more known for high performance distribution transformers which mitigate the operation and maintenance problems associated with conventional transformers. CSP technology enables a transformer to protect itself from secondary faults, lightning protection, persistent severe overloads, and provides visual warning of the overload conditions. CSP technology also protects the distribution system to which it is connected, in case of its failure. This means, that in case of failure of the transformer, it gets isolated from the system. Components and benefits of the CSP System CSP System has four essential components. They are: 1. Oil immersed Circuit Breaker for overload and secondary fault protection 2. Signal Light for indication during overload condition on transformer 3. HV Fuse for over-current, protection by isolating a failed transformer from the system the transformer by tripping and prevents any thermal damage occurring to the transformer. Besides protecting from secondary fault, the breaker also provides thermal protection to the transformer. It is an electro mechanical device with three major elements. These elements are: Temperature sensing through the use of bimetallic strips which are built into the breaker such that the load current flows through them. The bimetallic strips responds thermally to the temperature of the transformer oil and also to the temperature changes created by the flow of the load current through them Latching and tripping functions The signal light latch The emergency control assembly The magnetic trip device It works as Current interrupter Signal Light The signal circuit is mechanically connected to the circuit breaker latching and bimetal systems through an auxiliary contact. A signal light is mounted on the wall of the transformer tank. It gives a visual external indication when the transformer oil temperature reaches a specified preset value of temperature during overload condition. Once the signal light glows then it can be turned off only by manually operating the external handle of the circuit breaker.
Kotsons Private Limited
Deals in Alwar Call Now8047824280,7157WhatsApp
High Voltage Lightning Transformers
Price On RequestWe are an unparalleled name in offering a premium quality range of High Voltage Lightning Transformers. These High Voltage Lightning Transformers are made from very high quality raw material which ensures hassle free work performance at its user end. These transformers are widely finds its applications in various electrical sectors.
Duttsuri Industries
Deals in Alwar Call Now8047641455,4627WhatsApp
315 KVA Completely Self Protected Transformer
Price On RequestWinding Material: Copper
Product Material: Metal Sheet
Finishing: Polished
Color: Grey
Kotsons Private Limited
Deals in Alwar Call Now8048208690,6350WhatsApp
Instrument Transformers

Price On RequestSkipper has pioneered the design and manufacture of Instrument
Transformers over the past three decades. Skipper Instrument
Transformers are globally known for consistent accuracy, reliability and
maintenance-free operation over life time. Skipper manufactures the
entire range of Instrument Transformers viz. : Oil Filled, Outdoor Resin Cast, Indoor/Outdoor Metering Units, Indoor/Outdoord
Oil Filled Current Transformers
Skipper manufactures Oil Filled Current Transformers upto 220 kV class. Skipper make transformers are currently in operation
in challenging locations and have been delivering outstanding performance consistently for over 25 years. These
transformers comply with international quality, safety and environment specifications standards.
Outdoor Potential Transformers
Skipper complements its range of Current Transformers with Potential Transformers. The PTs are usually built up of multi cores designed for Metering and Protection in dead tank construction.
The PTs built in stacked core construction employ high permeability cold rolled grain oriented magnetic steel. The PTs are designed and manufactured in accordance with specific
user s specification and are suitable for Indoor / Outdoor application.
Skipper is equipped to Design and
Manufacture PTs upto 220 kV Class system voltage, with in-house
Testing facilities for conducting all routine Tests. However, Skipper also conducts Type and Special Tests to validate the design at
outside NABL accredited Test Laboratories like CPRI and ERDA.
Design
Oil filled current transformers use
current transformation principle to convert highline current (in HV
system) to a low current reduced by a fixed ratio. The current
transformers are designed generally in live tank construction for
optimum performance.
The primary winding is manufactured from copper conductor and is placed in the top housing.
The windings are rigid, concentric
with uniformly distributed secondary winding to deliver high mechanical
strength against short circuit forces.
The secondary windings and the cores are
contained in closely fitting rigid shell. The shell is fully insulated
from the top housing. The secondary leads are taken to the base passing
through a hollow insulator.
Insulation is provided by electrical
grade high grade Kraft paper. The fully assembled CTs are dried and oil
filled under vacuum in evacuated heating chambers. Optimum insulation
and long life is achieved by drying the paper insulation by heat in
vacuum. Oil, impregnated under vacuum, complements the insulation.
Construction
Skipper uses brown glazed porcelain
insulator with shed profile as per IEC 60815 for the CTs. Optionally
grey shade porcelain and other profiles can be offered as per specific
requirements. The porcelain insulator is cemented to flanges on both
ends for maximum mechanical strength. The top housing contains core coil
assembly and is made of corrosion resistant aluminum alloy.
The top of the tank has an oil
filling plug. The CT is protected from the vagaries of weather and can
withstand extreme temperature variations. Core of wound ring type are
manufactured from high quality silicon steel. However, Mu-metal cores
are used for select applications. Design, material and process selection
ensure that all requirements relating to metering and
Skipperseil Limited
Deals in Alwar Call Now8047851706,1723WhatsApp
Completely Self Protected Distribution Transformers

Price On RequestApplicable Standards : IEC / ANSI /BS / IS / EN /GOST Wide range of CSP transformers in accordance to above standards with different combinations can be manufactured. The CSP transformers are generally designed and manufactured to comply with the IEC publications 60076. CSP feature can be provided in the following range of transformers. Single Phase: 5kVA-167 kVA, Three Phase: 10 kVA-400 kVA, Insulation level 12 KV 24 KV 36 KV Indoor / Outdoor installation Conductor : Copper or Aluminum as per customer requirement CRGO / Amorphous as per customer requirement Hermetically sealed type (with gas cushion / fully filled) / Conventional type (with Conservator) Color : as per customer requirement Cooling arrangement : Corrugation or Pressed steel Radiators Maximum ambient temperature : as per customer specification Top oil Temperature rise : as per customer specification Average winding temperature rise : as per customer specification Concept of CSP transformers CSP technology is more known for high performance distribution transformers which mitigate the operation and maintenance problems associated with conventional transformers. CSP technology enables a transformer to protect itself from secondary faults, lightning protection, persistent severe overloads, and provides visual warning of the overload conditions. CSP technology also protects the distribution system to which it is connected, in case of its failure. This means, that in case of failure of the transformer, it gets isolated from the system. Components and benefits of the CSP System CSP System has four essential components. They are: 1. Oil immersed Circuit Breaker for overload and secondary fault protection 2. Signal Light for indication during overload condition on transformer 3. HV Fuse for over-current, protection by isolating a failed transformer from the system Oil Immersed Secondary (Low Voltage) Circuit Breaker The oil immersed circuit breaker is installed on the secondary (low voltage) side of the transformer. It provides the entire over current protection to the transformer and responds to secondary faults external to the transformer by tripping and prevents any thermal damage occurring to the transformer. Besides protecting from secondary fault, the breaker also provides thermal protection to the transformer. It is an electro mechanical device with three major elements. These elements are: Temperature sensing through the use of bimetallic strips which are built into the breaker such that the load current flows through them. The bimetallic strips responds thermally to the temperature of the transformer oil and also to the temperature changes created by the flow of the load current through them Latching and tripping functions The signal light latch The emergency control assembly The magnetic trip device It works as Current interrupter Signal Light The signal circuit is mechanically connected to the circuit breaker latching and bimetal systems through an auxiliary contact. A signal light is mounted on the wall of the transformer tank. It gives a visual external indication when the transformer oil temperature reaches a specified preset value of temperature during overload condition. Once the signal light glows then it can be turned off only by manually operating the external handle of the circuit breaker.
Kotsons Private Limited
Deals in Alwar Call Now8047652004,7055WhatsApp
Instrument Transformers
Price On RequestSkipper has pioneered the design and manufacture of Instrument
Transformers over the past three decades. Skipper Instrument
Transformers are globally known for consistent accuracy, reliability and
maintenance-free operation over life time. Skipper manufactures the
entire range of Instrument Transformers viz. : Oil Filled, Outdoor Resin Cast, Indoor/Outdoor Metering Units, Indoor/Outdoord
Skipper Electricals India Limited
Deals in Alwar WhatsApp
Instrument Transformers

Price On RequestSkipper has pioneered the design and manufacture of Instrument Transformers over the past three decades. Skipper Instrument Transformers are globally known for consistent accuracy, reliability and maintenance-free operation over life time. Skipper manufactures the entire range of Instrument Transformers viz. : Oil Filled, Outdoor Resin Cast, Indoor/Outdoor Metering Units, Indoor/Outdoord
Oil Filled Current Transformers
Skipper manufactures Oil Filled Current Transformers upto 220 kV class. Skipper make transformers are currently in operation
in challenging locations and have been delivering outstanding performance consistently for over 25 years. These
transformers comply with international quality, safety and environment specifications standards.
Outdoor Potential Transformers
Skipper complements its range of Current Transformers with Potential Transformers. The PTs are usually built up of multi cores designed for Metering and Protection in dead tank construction.
The PTs built in stacked core construction employ high permeability cold rolled grain oriented magnetic steel. The PTs are designed and manufactured in accordance with specific user s specification and are suitable for Indoor / Outdoor application.
Skipper is equipped to Design and Manufacture PTs upto 220 kV Class system voltage, with in-house Testing facilities for conducting all routine Tests. However, Skipper also conducts Type and Special Tests to validate the design at outside NABL accredited Test Laboratories like CPRI and ERDA.
Design
Oil filled current transformers use current transformation principle to convert highline current (in HV system) to a low current reduced by a fixed ratio. The current transformers are designed generally in live tank construction for optimum performance.
The primary winding is manufactured from copper conductor and is placed in the top housing.
The windings are rigid, concentric with uniformly distributed secondary winding to deliver high mechanical strength against short circuit forces.
Skipper Healthcare Private Limited
Deals in Alwar Call Now8047832607,7091WhatsApp
Completely Self Protected Distribution Transformers
Price On RequestWide range of CSP transformers in accordance to above standards with
different combinations can be manufactured. The CSP transformers are
generally designed and manufactured to comply with the IEC publications
60076. CSP feature can be provided in the following range of
transformers.
Kotsons Private Limited
Deals in Alwar Call Now8047794401,6387WhatsApp
Isolation Transformer
Call Now8047696728,6961Get Best Price
Control Transformer TSMU0330
Call Now7942822354Get Best Price
Isolation Transformers
Call Now7948548737Get Best Price
Isolation Transformers
Call Now8043816457,1461Get Best Price
Isolation Transformers
Call Now8047798949,3118Get Best Price