Building Structure Audit Service
Request a QuoteService Mode: Offline
Payment Mode: Online And Offline
Structural Audit , for building repair means everything connected to the conduct of a Building structure, which includes strength of the buildings Columns, Beams, Pillars, Iron Bars Plaster, Sewage discharge systems, Water pipeline systems, Podiums a) Structural Audit "parameters" will vary for Residential buildings, Commercial buildings and Industrial buildings. b) Some quack type Structural Auditors, perform a superficial check and issue a manipulated Structural Audit Report, to the Society, with the connivance of the apathetic Society office bearers. The Structural Engineer, mandatory (NDT tests for 30 yrs aged or above) must be a NEUTRAL authority, more so since any manipulations or fabricated or untrue Structural Audit Report, would mean, criminal prosecution against the Structural Engineer. An experienced competent Structural Engineer for any kind of building restoration repair and painting works would conduct several Non destructive tests after removal of plaster from the surface to determine the extent of corrosion, distress and loss of strength in concrete steel. Some of the tests means Non Destructive Testing commonly known as NDT testing techniques: a) Concrete Core Cutting Compression testing for columns, beams and slabs for Strength Assessment of concrete. b) Half Cell Potential test for determining the probability of corrosion in the embedded steel. c) Carbonation test for carbonation depth measurement for Steel. d) Ultrasonic Pulse Velocity Test (UPV) for Strength Assessment of concrete. e) Integrity tests for pile foundations and various testing techniques.