Ehvs-T- Energy High Voltage Splice Three Piece
₹ 49,501/PieceSplice Type: Heat Shrink Splice
Conductor Size: 50–95 mm²
Conductor Material: Copper
Insulation: Heat Shrink Insulated
Power Cable Corporation
Call Now7949346199WhatsApp
FIS-1140-12 - Elastomeric Lab Splice (12/Pk)
Call Now8047697593WhatsApp
Raychem HVS 1524S Heat Shrink Cable Splice
Call Now8047781052WhatsApp
3M Scotchcast Inline Resin Splice Kit
₹ 6,500/PieceGrade Standard: Industrial
Type: General Purpose
Product Type: Finished Product
Material Compatibility: Plastic
Royal Industrial Corporation
Call Now8047645704WhatsApp
MULTICOMP PRO Wire Splices QUICK SPLICE BLADE, BLUE, 14-18AWG, PK25, 878106 (Pack of 25)
₹ 813/PieceType of Product: Wire Splices
Name of Manufacturer/Packer/Importer: FARNELL
Ordering ID: 9972340
Manufacturer Part Number: 878106
IB Monotaro Private Limited
Call Now8047697506WhatsApp
Commscope 4-2122146-3 FMS-K-2-B-I-LOM4-12-IN99-24-SP Splice Panel
₹ 9,500/PieceBrand: Commscope
Model: 4-2122146-3 FMS-K-2-B-I-LOM4-12-IN99-24-SP
Body Style: Symmetrical
Cable Exit Location: Rear, left side | Rear, right side
Ocimum Systems Private Limited
Call Now8047619867WhatsApp
Panduit Splices, MOQ: 20000 Qnty
₹ 2/PiecePower/Voltage: Available in sizes from #26 - 10 AWG
SplicesPanduit Pan-Term Splices are designed and manufactured for fast assembly,and long reliable performance. As the demand for splices increases, it becomesessential to provide a complete system for termination products. We provide anextensive line of tooling designed specifically to provide optimum performancewhen used as a system for terminating. Suitable for in-line, parallel, and group splicingof wires Nylon and vinyl insulated as wellas non-insulated Available in sizes from #26 10 AWG Internal wire stops on butt splices prevent overinsertion of wires
Suvaca Technologies Private Limited
Call Now8047544045WhatsApp
AnodeFlex 1500 In-Line Splice Kit

Price On RequestPower/Voltage: 1500
Product Description
The AnodeFlex 1500 In-Line Splice Kit is designed to connect together two AnodeFlex 1500 anode strands to a lead wire.
The heat-shrinkable tubing, sealant and accessories, have been specifically designed to environmentally protect the electrical connection in direct burial soil applications during the whole anode life.
The long term performance of AnodeFlex 1500 is conditional upon keeping the base copper conductor and electrical connection isolated from water. Only AnodeFlex splice kits are recommended for any connection to AnodeFlex 1500. The sealing performance has been tested for over 5 years of real time accelerated tests. Our field and lifetime experience with this product now exceeds 20 years.
The heat-shrinkable components are made of a radiation-crosslinked polymer. The cable and anode are wrapped with mastic, which flows when heated to ensure a very tight seal. When the sleeve is heated with a torch, or a heat gun, it shrinks tightly around the anode. Once installed, the In-Line Splice kit withstands the normal wear and tear of a construction environment and is extremely corrosion resistant. Impact, internal pressure and penetration resistance have all been tested following the telecommunication requirements for telephone cable splices. The installation is easy and can be completed in few minutes by a trained technician.
Himoya Corrosion Technology Private Limited
Call Now7942789963WhatsApp
Splice Joint For Rubber And Pu Timing Belt
Price On RequestWe Madhav Engineering Co. are acknowledged organization and are Sole Proprietorship based firm, engaged as Wholesaler and Trader of PVC Conveyor Belt, Timing Belt etc.
Madhav Engineering Co.
Call Now8043882625WhatsApp
6 Inches Aluminum Compression Cable Splice
₹ 125/PieceShape: Cylindrical
Product Material: Aluminum
Product Finish: Polished
Color: Silver
The Tarama Industries
Call Now8043882688,3393WhatsApp
Splicing

Price On RequestWe terminate fiber optic cable two ways - with connectors that can mate two fibers to create a temporary joint and/or connect the fiber to a piece of network gear or with splices which create a permanent joint between the two fibers. These terminations must be of the right style, installed in a manner that makes them have little light loss and protected against dirt or damage in use. No area of fiber optics has been given greater attention than termination. Manufacturers have come up with over 80 styles of connectors and and about a dozen ways to install them. There are two types of splices and many ways of implementing the splice. Fortunately for me and you, only a few types are used most applications. Different connectors and splice termination procedures are used for singlemode and multimode connectors, so make sure you know what the fiber will be before you specify connectors or splices! Connectors Since fiber optic technology was introduced in the late 70s, numerous connector styles have been developed. Each new design was meant to offer better performance (less light loss and back reflection), easier and/or termination and lower cost. Of course, the marketplace determines which connectors are ultimately successful. Connector and Splice Loss Mechanisms Connector and splice loss is caused by a number of factors. Loss is minimized when the two fiber cores are identical and perfectly aligned, the connectors or splices are properly finished and no dirt is present. Only the light that is coupled into the receiving fiber's core will propagate, so all the rest of the light becomes the connector or splice loss. End gaps cause two problems, insertion loss and return loss. The emerging cone of light from the connector will spill over the core of the receiving fiber and be lost. In addition, the air gap between the fibers causes a reflection when the light encounters the change n refractive index from the glass fiber to the air in the gap. This reflection (called fresnel reflection) amounts to about 5% in typical flat polished connectors, and means that no connector with an air gap can have less than 0.3 dB loss. This reflection is also referred to as back reflection or optical return loss, which can be a problem in laser based systems. Connectors use a number of polishing techniques to insure physical contact of the fiber ends to minimize back reflection. On mechanical splices, it is possible to reduce back reflection by using non-perpendicular cleaves, which cause back reflections to be absorbed in the cladding of the fiber. The end finish of the fiber must be properly polished to minimize loss. A rough surface will scatter light and dirt can scatter and absorb light. Since the optical fiber is so small, typical airborne dirt can be a major source of loss. Whenever connectors are not terminated, they should be covered to protect the end of the ferrule from dirt. One should never touch the end of the ferrule, since the oils on one's skin causes the fiber to attract dirt. Before connection and testing, it is advisable to clean connectors with lint-free wipes moistened with isopropyl alcohol. Two sources of loss are directional; numerical aperture (NA) and core diameter. Differences in these two will create connections that have different losses depending on the direction of light propagation. Light from a fiber with a larger NA will be more sensitive to angularity and end gap, so transmission from a fiber of larger NA to one of smaller NA will be higher loss than the reverse. Likewise, light from a larger fiber will have high loss coupled to a fiber of smaller diameter, while one can couple a small diameter fiber to a large diameter fiber with minimal loss, since it is much less sensitive to end gap or lateral offset.
Maruti Fiber Co.
Call Now8043879897,3118WhatsApp
Optical Fiber And Copper Splice
Price On RequestSee the NextGen"s wide range of Optical Fiber and Copper Splice closures with international standerds widely exported for telecommunication, PON,Railway and Military use.
Riddhi Infratel
Call Now8047667422,5434WhatsApp
Butt Splices
Price On RequestApplication For use with all types of electrical copper cable fittings. To secure overhead line distribution connection system. Options Type: With or without bell mouth With or without inspection hole Plating
Jainsons India
Call Now8043809376WhatsApp
Cable Splices
Call Now8047676552,1648Get Best Price
Cable Splices
Price On RequestBeing an eminent organization in the industry, we are involved in providing a premium quality range of Cable Splices. Features:
Highly durableSturdinessPrecisely designed
D.P. Patel
Call Now8047810335,5527WhatsApp
Parrell Splice
Call Now8047546223,8279WhatsApp
Splices
Call Now8047697802,9145WhatsApp
Butt splice
Call Now8047312257,1929WhatsApp
Splicelam Laminate
Call Now8043844601,6104Get Best Price
Spalling Resistance
Call Now8048264584,9688WhatsApp
Copper Compression Splices
Price On RequestCopper Compression Splices
Gemtech
Call Now8043823811,5105WhatsApp
Zd Plise
Call Now8047673446,5586Get Best Price
splice wood
Call Now8043879897,6317WhatsApp
Distribution Cable Splices and Cable Joints
Price On RequestG&W offers a variety of distribution cable splices and cable joints for a wide variety of cable types through 35kV. The product line extends from simple tape splice kits to innovative epoxy molded designs providing elbow interfaces for quick disconnect and reconnect of the cable sections. Cable joints can be installed within underground vaults or direct buried.
G&W Electric Company India Private Limited
Call Now8047690293,4317WhatsApp
Fiber Cable Splicing

Price On RequestUnited Communications specializes in Fiber Optic Cable placement, Splicing Testing services. We can get your network installed and operational within scheduled time frame and estimated budget. Our prices are very reasonable and we provide high quality service. We are providing these services nationwide to a variety of industrial clients. We have executed wide range of multidiscipline projects for large organization across Pan India. We are glad to provide our prestigious client references upon your request. Fiber Cable Placement Services: Blowing Optical Fiber CablePlacement of Inner ductPlacement of manholesPlacement of Fiber cable (all sizes) Fiber Splicing Testing Services: Fiber optic splicing (fusion and/or mechanical)Fiber Optic Testing Services, includes end to end, reel testing, splice loss, Optical Return Loss, and Power Meter/Laser Source TestingFiber Optic Connectorization and polishingCustom cable assembliesEmergency restoration Our technicians are highly skilled in all aspects of splicing, testing, emergency restoration, etc... We utilize state-of-the-art fusion machines to maintain: Maximum efficiencyLower splice lossProvide superior performance on your network
United Communications
Call Now8043804496,4460WhatsApp
Ehvs - Inline And Shield Break Splice From 123kv Up To 170kv
Price On RequestEHVS joint is a pre-fabricated three-piece design for voltage classes up to 170kV. Polymer insulated cables of various designs can be adopted with respect to shielding and metal sheath. Cross-section up to 250 mm2 is applicable Pre-fabricated three-piece splice design Using torque-controlled conductor sleeves Short cut-back dimensions Integrated moisture barrier using H/S components Can adapt shield-break application Pre-fabricated and tested Si-rubber Type tested according to IEC 60840 and IEEE 404 standards
Raychem RPG Private Limited
Call Now8047649405,1806WhatsApp
Cable Splicing
Call Now8043883960,8360Get Best Price
OPGW Joint Closure

Price On RequestItem Code : TENDO/JB/001Application : Suitable for OPGW On HT/ EHT Tower, can be installed aerially, direct Fit to the ower. The cable entry port can be 1 into 2, 2 into 2. F 1. High-strength insulation shell, well sealed with Aluminum Allays & Gunmetal connector2. Can be installed and opened without special tools, can be opened repeatedly3. Suitable for 8/12/24/48 non-ribbon cable4. Reliable grounding system5. Modular installation, easy configuration 6. Complete accessories, easy operation and maintenance. 7. The shell is formed by two semi-circular enclosures, horizontal installation 8. There's no attenuation on the fiber connectors during the installation of the optical able splice closure. Technical Parameter : The axial tension of 2000N without leakElectric strength : 15KvImpact of tightness: 16N*m for three times without rift or leak Meet the requirement of YD/T814-1996Fire-protection rating : UL94 VO 70Kpa-106KpaWorking conditions : Ambient temperature:-40 c-+80 cRelative humidity : 85%(30 c)Baiometric pressure : level of protection(EN60529):IP54,IP58
Ten Dot Infra Private Limited
WhatsApp