Electric Capacitance Level Measurement, For Capacitive Rod Probe
₹ 1,98,000Power Source: Electric
Model Name/Number: Standard
Usage/Application: Capacitive rod probe
Warranty: 1 year
Biofluid Control Systems
Call Now7942558658WhatsApp
Electric Supply MEASUREMENT OF LEVEL BY CAPACITANCE METHOD, For Lab Experiment
Call Now8047634811WhatsApp
Capacitive Level Measurement, Model Name/Number: Cg/Cgm Series
Call Now8047632056WhatsApp
Capacitance Level Transmitter

₹ 10,800Usage: Industrial, Laboratory
capacitance is formed between the probe and the vessel wall .As the level of the measuring medium rises or falls capacitance between the probe and vessel wall changes proportionately. A high frequency sine wave is applied between the probe and tank wall. A change of medium level will induce a change in the current of the applied sine wave. From when the capacitance in the vessel increase, impedance will decrease and current will increase and vice-versa. (Z=Resistance, C=Capacitance, F= Frequency) Head mounted electronics converts the capacitance variation to 4-20mA signal for long distance transmission. It is provided with trimpots for SPAN and ZERO adjustments. With no moving parts it is free from wear and tear, rugged and robust in construction. No dead zone like float based instruments. It must be ensured that the probe is parallel to the tank wall throughout it's length. Technical Specification kabir make Capacitance type 3 wire Level transmitter Model (CLT-1) with non insulated probes for non-conductive liquids or PTFE Teflon insulated probes for conductive liquids.Frequecy of operation5 to15kHz.Probe MaterialStainless Steel / Teflon insulated 10/12/16 mm rod upto Max 3 Metre lengthProcess connection3/4",1",1.1/2" BSP(M) or 1 "ASA 150 lbs flanged but thickness 12mm (or as per customer specification)Power supply24VDCOutput 4 to 20 mA.(non-isolated)Span & Zero adjustmentTrim potsMax.Working Pressure10kg/sq.cmMax.Working Temp.150deg.CAccuracy 0.5%, 1% or 2%EnclosureCast aluminium weather proof with PG9 cable gland or Flame proof (IS2148-2004,Gr II A and B gases)Cable Size3 core, 0.75 sq.mm screened PVC cable. While sending enquiries for capacitance type level transmitters, please furnish following informations to enable us to submit a suitable offer:Name of service Medium/LiquidDielectric constant of the medium.Operating Temperature and pressure. Does the temperature vary? If so how much?Nature of liquid - Foaming, Viscous, Sticky etc.If agitation is involved whether sufficient space is available for probe between agitator and tank wall to avoid damage.Material of tank - Metallic or Non- MetallicIf mounted on nozzle, height of nozzle, with tank dimensions and drawings.
Om Industrial Services
Call Now8043813772WhatsApp
Keyence Capacitor TR-V1000 / 1000F / 25V
₹ 1,47,000Model:: TR-V1000
Type: Measuring Instrument Body 10-inch USB Panel
Controller Platform: TR-V series
Display: 10.4-inch TFT LCD 640x480 (VGA)
Star Automations
Call Now7942824650WhatsApp
Electric Capacitance Level Measurement, For Industrial
Call Now8043819806WhatsApp
CAPO 2.5 Capacitance and Dissipation Factor measurement
₹ 1Test Frequency: 10 Hz - 400 Hz
Panel Display: 5.7'' Color LCD with LED back lighting
Weight: 22.2 kg
Model Name/Number: CAPO 2.5
Laxmi Sales Corporation
Call Now7942534734WhatsApp
Capacitance Measuring Instrument And Capacitance And Dissipation Factor Tester
Price On RequestLCR measurement range: L - 20H(2kV)
LCR measurement accuracy: 0.1%
Angle resolution: 0.01
High voltage output: 0.5KV~10KV
Technosys Systems
Call Now8047636414WhatsApp
CAPO 2.5 Capacitance And Dissipation Factor Measurement
Call Now8047301757WhatsApp
UITM-11 Capacitance Measurement Trainer Equipment, For Training
Call Now8047523414,8101WhatsApp
Continuous Level Indicator
₹ 15,000Dependability, strength, durability, ruggedness are the keywords when it comes to the use of level instruments for continuous monitoring in difficult environment conditions. The ILC... series stands up to the requirements of a tough continuous level detector and offers the following benefits:Level measurement is displayed on a built-in Digital Panel Meter having 0.5 inch high digits for better visibility. Standard output signal of 0-5 V DC and 0/4-20 mA DC proportional to 0-100% level change available for remote indicators and recorders. 'In Situ' range selection and calibration possible from evaluation unit. Probe head accessibility not required. Measuring system has no moving parts so does not suffer any mechanical wear and tear and hence is maintenance free. Economical to install, since ordinary 3-core cable is used for interconnection. Flame-proof probe suitable for hazardous areas as per IS-2148 for group IIA and IIB is available.
Sapcon Instruments Private Limited
Call Now8047302247,9718WhatsApp
Electric CAPACITANCE LEVEL MEASUREMENTS, Rated Capacity: High, Model Name/Number: Standard
Call Now8047852034,9564WhatsApp
Capacitance Measurement
Price On RequestThe System offers a unique and superior testing methodology because it allows you to monitor partial discharge activity in both bushings and transformer using the same sensor set. Like power factor and capacitance changes, partial discharges are also indicative of insulation breakdown. Its houses six BNC connectors one for each phase of each winding which allow connection to our Partial Discharge Analyzer . Online periodic monitoring of partial discharge (arcing or sparking) can help provide a root-cause analysis of internal gassing or other discharge activity related to the winding insulation, internal connections, bushings, or magnetic core iron.
Logic Plus Plus India Pvt. Ltd.
Call Now8043819366,2690WhatsApp
Capacitance And Dissipation Factor
Price On RequestMeasurement Parameters: Capacitance and Dissipation Factor
Capacitance And Dissipation Factor
AFS Power Engineers
Call Now8043837514,4693WhatsApp
Precision Capacitance Measurement System
Price On RequestMeasurement of circuit capacitancesDielectric measurements10-5 pF to 11.1 F, 2- or 3- terminal0.01% accuracy, 1 ppm resolutionLever balance, in-line readoutReads dissipation factor or conductance
Advance Technical Systems Private Limited
Call Now8043838225,6855WhatsApp
Pointek CLS200

Price On RequestPointek CLS200 is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output, ideal for detection of liquids, solids, slurries, foam and interfaces. The digital version (with PROFIBUS PA) includes a display and provides additional diagnostic features. The Pointek CLS200 is offered in standard and digital versions.The standard version has 3 LED indicators with basic relay and solid-state switch alarms. The digital version provides an integral LCD display for standalone use, and also provides PROFIBUS PA communication (Profile version 3.0, Class B) for connection to a network. The power supply is galvanically isolated and accepts a wide range of voltages (12 to 250 V AC/DC for standard version and 12 to 30 V DC for digital version). The stainless steel and PPS (PVDF optional) materials used in the probe construction provide a temperature rating up to +125 C (+257 F) on the process wetted portion of the probe. The switch responds to any material with a dielectric constant of 1.5 or more by detecting a change in oscillating frequency, and it can be set to detect before contact or on contact with the probe.The CLS200 operates independently of the tank wall or pipe so it does not require an external reference electrode for level detection in a non-conductive vessel such as concrete or plastic. Key Applications: liquids, slurries, powders, granules, pressurized applications, hazardous areas.
Sharp Control Equipments Private Limited
Call Now8047798326,9765WhatsApp
Capacitance Level Measurement

Price On RequestContinuous level measurement and point level detection in liquids and solids with capacitance probes
Capacitance
level measurement with Liquicap is a simple and cost-effective solution
which offers a wealth of possibilities for level monitoring in liquids.
Particularly in small tanks and build-up forming media. Point level
detection works with Liquicap, Liquipoint, Minicap or Solicap
capacitance level switches also in applications involving aggressive
media and heavy build-up in liquids and solids. Check out the broad
range of capacitance level sensors and click on the button below.
Capacitance level measurement
Our product finder helps you to search for
suitable measuring devices, software or system components via product
characteristics. Applicator leads you through an individual product
selection via application parameters.
Capacitance
level sensors are a proved, as well as cost-effective solution for
level measurement and point level detection in liquids and bulk solids.
Various transmitters for continuous level measurement and switches for
point level detection are available. The measurement of interface is
also possible. The measuring principle is proven in millions of
applications.
Capacitance measurement: Measuring Principle
The
principle of capacitive level measurement is based on the capacitance
change of a capacitor. The probe and the tank wall form a capacitor
whose capacitance is dependent on the amount of product in the tank: An
empty tank has a lower, a filled tank a higher capacitance.
Benefits
Proven and tested measuring principle - robust and safe
Universally adaptable probe
Reliable operation also in strong build-up formation and viscous media
Easy commissioning
Saika Instruments & Solution
Call Now8047788472,5679WhatsApp
Capacitance Level Indicator
Price On RequestTo suit the variegated requirements of our customers, we are offering qualitative Capacitance Level Indicator. Our offered products are manufactured using the finest quality raw material and by employing modern methods and latest technology by our vendors. Our products are widely appreciated by our clients for their high quality attributes, rigid construction and longer serving life. We can also customize offered product as per the specifications given by our valued customers. Features:
Easy MaintenanceLower Operational CostApplication Specific Design
System Automation
Call Now8047682545,1072WhatsApp
MEASUREMENT OF LEVEL BY CAPACITANCE METHOD TEST RIG
₹ 6,000Manufacturer supplier of : mechanical engg ,civil engg ,automobile egg, aeronautical engg, instrumentation engg , tribology engg renawable energy laboraatory equipments for technical university , IIT, NIT, engineering colleges , diploma polytechnics ,industrial training institute industry.
Technical Teaching (D) Equipments
Call Now8043825475Get Best Price
Capacitance Level Measuring Instrument
Call Now8048251211,8893Get Best Price
Capacitance Level Indicator
₹ 14,560Pressure: PN20
Connection: DN20
Environment temperature: -50C~+80 C
Center to center distance: 1000 m
Scientific Flow Devices
Call Now8047852034,6728WhatsApp
AMBER-ATCS-500HT
Call Now8043806381,4349WhatsApp
Capacitance Measuring
Call Now8047684751,2043Get Best Price
Capacitance Continuous Level Indicator

Price On RequestDependability, strength, durability, ruggedness are the keywords when it comes to the use of level instruments for continuous monitoring in difficult environment conditions. The ILC... series stands up to the requirements of a tough continuous level detector and offers the following benefits:Level is displayed on a built-in Digital Panel Meter having 0.5 inch high digits for better visibility. Standard output signal of 0-5 V DC and 4-20 mA DC proportional to 0-100% level change available for remote indicators and recorders. "In Situ" range selection and calibration possible from evaluation unit. Probe head accessibility not required. Measuring system has no moving parts so does not suffer any mechanical wear and tear and hence is maintenance free. Economical to install, since ordinary 3-core cable is used for interconnection. Flame-proof probe suitable for hazardous areas as per IS-2148 for group IIA and IIB is available. As far as the service material is concerned, the ILC indicator can be used with conductive or non-conductive liquids, powdered or grained materials of homogeneous composition having stable dielectric constant. Our clients in the Oil, Food, Water treatment, Diesel, Chemicals etc. industries have used the ILC level indicator to their satisfaction. Technical Data Evaluation UnitHousing Cast Aluminium, Weather proof, back panel/wall mountingCable Entry 3 Nos. / 2 Nos.Max. Amb. Temp. -20o C to + 60o C.Power Consumption 5 VA approx.Mains Voltage 230 V or 110 V AC (-15% to +10%), 50 Hz; 24 V AC/DC; 90 to 260 V AC universal power supply. (to be specified while ordering).Relay Output One/two set (s) of potential free c/o contacts rated at 230V AC 6A, 50 Hz for non-inductive load per set point.Fail-Safe Mode Max. or Min. Field selectable.Indication Red LED for alarm, Green LED for normal, Yellow LED for system fault.Response Time 0.2 SecondSwitching Delay for Adjustable from 0.5 to 20 Second. for probe covered or uncovered condition.Connection to Electronic Insert 3 - core unscreened cable.Initial Capacitance 0 to 290 pf. in 3 overlapping ranges. (For single point switching) 0 to 1200 pf. in 3 overlapping ranges.(For pump control & multi point switching)Switching Hysteresis0.5 pF. typical. (For independent switching) & Continuously adjustable over the entire range. (For pump control switching) Electronic Insert - LDC 311Housing Plastic, potted in epoxy resin.Frequency 500 kHz. (approximately).Ambient Temp. -20o C to 80o C.Supply Voltage 15 V derived from evaluation unit.Output Signal 3 to 12 V DC. Probe A wide variety of probes with different mounting connections is available to suit various process applications. We offer specially designed ceramic insulated rod/rope probes suitable for operating temperatures max up to 600o C.
ENN Engineers Private Limited
Call Now8048201272,9355WhatsApp
Capacitance Level Indicator

Price On RequestCapacitance Level Indicator, Switch And Transmitter is ideally suitable for level measurement and control of liquids and some slurries of homogenous composition having a stable dielectric constant. The performance of these instruments is not affected by the properties of the liquid such as conductivity, corrosiveness and viscosity. Features: Microcontroller based design. Digitally Controlled relay output. Auto-tuning feature easily adapts to different sizes of tank and liquid. Simplified calibration procedure.Overflow visual indication Adjustment of parameters with the help of menu. TECHNICAL SPECIFICATIONS: Tank height / Range0 to 5 mtrs ConnectionFlanged to ASA/BS/DIN/ Screwed BSP/NPT Probe MaterialPTFE Insulated SS304 or SS316 or SS316L Enclosure ClassFlame-proof IP-65, IIA, IIB, IS:2147 CMRI/TC/H449 Enclosure MaterialDie Cast Aluminimum Lm6 InputLevel Retransmission Output4-20 mA DC, Optically Isolated Level Display4 Digit LED Relay outputPotential Free Contact (5A/230 VAC) Power Supply24 VDC / 150mA 10% Accuracy 2% of Full Scale Power Consumption TerminationThrough pin type lugs Operating Temperature0 to 200 C Operating Pressure0 to 25 Kg/cm2 Relative Humidity5 to 95 % RH, Non-Condensing
Cbro Incorporation
Call Now8043868954,7675WhatsApp
Measurement of Inductance And Capacitance
WhatsApp
Measurement of Inductance And Capacitance

₹ 5,000Measurement of Inductance And Capacitance (Model No: Electronics Lab ELE107 (Measurement of Inductance And Capacitance) )Measurement of Inductance And Capacitance from Electrical Electronics Lab India Measurement Of Inductance Capacitance By Maxwells L C BridgeExperimental Training Board has been designed specifically for the study of Maxwell s L/C Bridge. Using this bridge the value of unknown capacitor or an unknown inductor can be found. The board is absolutely self contained and requires no other apparatus. Practical experience on this board carries great educative value for Science and Engineering Students.Object: To study Maxwell s L/C Bridge. 1. To measure value of unknown capacitance. 2. To measure value of unknown Inductance.
Features: The board consists of the following built-in parts: 1. 12V D.C. at 100mA, IC regulated Power Supply internally connected. 2. 1 KHz Sine Wave Oscillator. 3. Audio Amplifier and speaker for null detection. 4. Five unknown values of capacitors selectable by a band switch. 5. Three unknown values of inductors selectable by a band switch. 6. Two decade resistances in 100 ohm steps. 7. Potentiometer and adequate no. of other electronic components. 8. Mains ON/OFF switch, Fuse and Jewel light for Engineering Electronics Workshop Laboratory Instruments
Naugra Export
Call Now8047640218,8007WhatsApp
Limit detection
Price On RequestLimit detection Protect your application from overflow or dry-running
Pepperl Fuchs Company
Call Now8047834569,3828WhatsApp