List No: r
Sample scanning range: 100 um x 100 um x 15 um (+-10 %)
Scanning type by sample: XY non-linearity 0.05 %; Z non-linearity 0.05 %
Laser wavelength: 1300 nm, non-interfering with spectroscopic detector
Signal to Noise Ratio (SNR): 500:1
Maximum Sample Frequency: 285 Hz
Sample Type: Organic Sample
f-number (f/#): 1.3
Brand: Raman
Model Name/Number: Raman Microscope - 3785
Wavelength Range: 190-900 nm
Optical System: Single Beam
Spectral coverage: 150-3425 cm-1 (532 nm)
Laser Wavelength: 532 nm
Form Factor: Benchtop
Spectral Range: 200-2000 cm-1
Signal to Noise Ratio (SNR): 1000
Laser excitation wavelength: 532, 638,785,1064nm
Maximum Sample Frequency: 1khz
Brand: Raman
Size: < 6 Kgs
Spectral Resolution: 3 cm-1/pixel
Measurement Mode: Raman/PL/OES
CCD Cooling: 1 stage TE Cooled, (2 stage optional)
Laser Wavelength: 633 nm
Usage/Application: Laboratory Use
Brand: ThermoFisher
Model: TruScan GP
Dimensions: 8.2 x 4.2 x 1.7 in
Brand: Labindia
Model Name/Number: LABORAM
Usage/Application: Plant Use
Warranty: 1
Laser class: 1 for Direct model 3B for Fiber model
Laser Wavelength: 532 nm/785 nm/1064 nm
Form Factor: Benchtop
Spectral Range: 200 cm-1 to 3500 cm-1 for 532 nm 100 cm-1 to 2300 cm-1 for 785 nm and 1064 nm
Measuring principle: Raman spectroscopy
Spectral coverage: Starter: 300-3300 cm-1 (785 nm) Base Model: 150-4350 cm-1 (532 nm) 150-3425 cm-1 (785 nm) 200-2400 c
Ambient temperature: Operating: 15 to 30 DegreeC 59 to 86 DegreeF Storage: -15 to 50 DegreeC 5 to 122 DegreeF
Input voltage: 100-240 V, 50-60 Hz, +-10%
Brand: Raman
Model Name/Number: HR-TEC Series
Wavelength Range: 190-1100 nm
Optical System: Single Beam
Laser Wavelength: 785 nm
Form Factor: Handheld
Spectral Range: 400 - 2300 cm-1
Wavelength Range: 785nm
Laser Wavelength: 532 nm
Form Factor: Portable
Spectral Range: 200-4000 cm-1
Detector Type: CCD
Brands
Seller Type
Signal to Noise Ratio (SNR): aman spectrum study of solid and liquid samples like TiO2, CeO2, Sulfur, Urea, Cyclohexane, CCl4, et
Laser excitation wavelength: aman spectrum study of solid and liquid samples like TiO2, CeO2, Sulfur, Urea, Cyclohexane, CCl4, et
Maximum Sample Frequency: aman spectrum study of solid and liquid samples like TiO2, CeO2, Sulfur, Urea, Cyclohexane, CCl4, et
Brand: Raman
Laser Wavelength: 1064 nm
Form Factor: Benchtop
Spectral Range: 100-3200 cm-1
Detector Type: CMOS
Brand: Bruker
Measurement Mode: Raman Scattering
Material: Hard Polycarbonte
Sample Form: Solid,Liquid And Films
Brand Name: Serstech
Color: Black
Usage: Used to identify materials
Material: Plastic
Operative System: Android
Excitation Wavelength: 0.5nm
Wavenumber Range: 4000 cm
Resolution: 10 cm-1
Brand: Raman
Model Name/Number: HR-TEC Series
Wavelength Range: 900 mm
Optical System: Double Beam
Grating Size: 76 mm x 76 mm
Flat Field Size: 30 mm x 12 mm
Wavelength Accuracy: +/-0.20 nm
Repeatability: +/- 0.075 nm
Wavelength Range: 190-900 nm
Optical System: Single Beam
Model Name/Number: HR-TEC Series
Spectral Bandwidth: 2 nm
Brand.: Metrohm
Model.: MIRA
Capacity: 400-2300 cm-1
CAT No: 29270010
Battery: 14.4 V Li-ion, 3100 mAH, Greater than 5 hrs
Data Transfer: Transfer results via WiFi or USB
Excitation Wavelength: 1064 nm
External Power: 100~240VAC, 50-60Hz, +18V DC, 2.5A
The MultiRAM configuration provides a spectral range: 3600 - 50 cm-1
Brand: Raman
Photometric Range: spectral range of 3600 - 50 cm-1 (Stokes shift)
Detector: Germanium detector
Laser Wavelength: 785 nm
Form Factor: Portable
Spectral Range: 250 to 2875 cm-1
Detector Type: NA
Dimensions: With frame 192 x 266 x 351 mm3
Spectrum Range: 100 cm-1 ~ 3600 cm-1
Laser Output Power: 40mW / 40 mW / 20mW
Laser Wavelength: 532 to 785 nm