Power Quality Audit
Request a QuoteVoltage Level: Mixed System
System Voltage: Mixed System
Energy Audit Services Baseline assessment:Utility bill analysis, demand profiles, load factor, tariff alignment, and variance checks to check abnormal consumption trends. Asset and process survey: Equipment inventory duty cycles, schedules and Specific Energy Consumption baselining by system. Measurement and verification plan: Metering strategy for feeders/major loads, KPIs and M V protocols aligned to targeted savings. Load profiling: Track demand trends, peaks, diversity factors, weekday/weekend and seasonal patterns to optimize contract demand and avoid penalties. Power factor improvement: KVAR sizing, automatic/thyristor banks, SVG/AHF recommendations, capacitor health, and payback modeling tied to penalty removal. HVAC, compressed air, motors: Efficiency benchmarking, leak/compressed air studies, VFD applicability, sequencing, and controls tuning for operational savings. Tariff and TOU optimization: Feeder segregation, load shifting/levelling, captive/renewable dispatch strategies to lower landed kWh cost. Implementation roadmap: Ranked ECMs with capex/opex, savings, ROI, risk, and an M V plan for post‑implementation verification. Power Quality Audit Services PQ measurement campaign: Deployment of qualified personnel with Class‑aligned analysers for synchronized logging of voltage, current, power, harmonics, flicker, dips/sags, swells, interruptions, unbalance, RVC, frequency, and transients. Event and waveform analysis: Triggered captures for inrush, capacitor switching, transformer energization, VFD trips, UPS transfer, and lightning/switching surges with pre/post event windows. Harmonics and interharmonics: THD, harmonic power and phase to the 50th order, interharmonics, spectra, and compliance benchmarking against internal limits. Flicker assessment: Short‑term and long‑term indices to diagnose visible flicker and voltage stability problems in welding bays and large motor starts. Voltage quality compliance: Sags, swells, interruptions, RVC, unbalance, and frequency deviation with time correlation to PLC faults and process upsets. Power factor and demand quality: KWH, KVA, KVAR, KVARH, displacement vs true PF, kvar sizing, penalty elimination, and demand spike diagnosis. Neutral and transformer stress: K‑factor implications, triplen harmonics, neutral overcurrent, overheating risk, and derating recommendations. DC bus and hybrid systems: AC/DC power and ripple on VFD DC links, rectifier/UPS fronts, PV/DC‑coupled or battery‑backed plants. Deliverables Executive summary: Listing of issues with quantified impact on energy cost, downtime risk, quality loss, and prioritized corrective actions with payback. Detailed annexures: Time‑correlated PQ plots and trends, event logs, harmonic spectra, flicker indices, unbalance metrics, and compliance dashboards. Recommended BOM: Capacitors/SVG/AHF sizing, CT/PT specs, filters/tuning, earthing/shielding improvements. M V plan: Post‑fix verification steps, KPIs, and logging templates to validate sustained improvement and track ROI over time. Use Cases We Cover Nuisance trips, PLC/drive faults, and process upsets tied to sags, swells, transients, and inrush. Harmonics compliance and mitigation for VFDs, welders, rectifiers, and UPS systems, including resonance checks. High bill investigations PF penalties, contract demand spikes, TOU misuse, and feeder misallocation. Lighting flicker and voltage stability in large shops, weld bays, and lines with frequent motor starts. Mixed AC/DC sites, PV/DC‑coupled and battery‑integrated systems, UPS/IT loads.