Compressed Air Audit Services
Request a Quote Equipment / Instruments used in air audit:
Fluke make power analyzer [438 II] for measuring electrical energy parameters [45+ parameters] and making trends for detailed electrical energy proposals
The compressed airflow meter [especially for compressed air wet/dry. mass thermal and differential pressure]: velocity [scfm], pressure [bar], temperature [deg C], baseload, and variable load with standard condition
Temperature gun, Humidity data logger-air ambient temperature [deg C] relative humidity [%]
The water flow meter: velocity [lpm], pressure [bar], temperature [deg C], actual water consumption quantity
All type of refrigeration and desscent dryers performance and dew point transmeter [deg C] measurement
Power analyzer and flow meter for electrical , mechanical,Pnematic energy consumption
Air audit scope of work in the total compressed air system
1 Compressed air generation end:
1. Detailed performance study of Compressors in terms of [velocity [scfm], pressure [bar], temperature [deg C] and specific power [kW/cfm],load unload power.
2. Detailed performance study of air compressors,accessories,and dryers [operating, designed, and actual requirement]
3. All types of dryers and downstream accessories' performance measurement [dew point from +20 to -70 deg c], pressure drop, and purge loss quantification with analyses.
4. Plant/department air consumption trends:minimum 24, maximum 72hours air generation input electrical energy, outlet mechanical energy [airflow, air pressure, power temperature] againstthe actual requirement and plant production detailed site measurement.
5. Detailed analysis of the location/installation of the existing air compressorsand air ventilation inside the compressor room against outside ambient air.
2 The compressed air transmission system
6. Analysis of the distribution of compressed air systems in the piping department and air pressure drop department-wise. Actual air requirement and actual flow travelled for that air pressure drop.
7. Analysis of the distribution of compressed air system accessories. Air receivers" capacity against air generation, designed capacity against air dryer'send-user application requirement, and any other problems in your Compressed AirSystem.
8. Plant air leakage measuring with quantification of the department-wise [end user and main header pipeline]. Based on the needs, additional costs will be charged [day-wise]; we will use ultrasonic leak detection [identification] with tagging [Small, Medium Big], leakage location photocopy and description
9. During the air leakage measurement, plant production stoppage is required [time duration will change according to the plant capacity]; this leads to a better understanding of the compressed air system leakageroot cause